Features
- Frequency range 10 MHz to 8.0 GHz
- 3 axis isotropic measurements of EMF
- Non-directional (isotropic) measurement with three-channel measurement probe
- High dynamic range
- Configurable alarm threshold and memory function
- Easy & safety to use
- High frequency (RF) electromagnetic wave field strength measurement
- Mobile phone base station antenna radiation power density measurement
- Wireless communication applications (CW, TDMA, GSM, DECT)
- RF power measurement for transmitters
- Wireless LAN (Wi-Fi) detection, installation
- Spy camera, wireless bug finder
- Cellular or Cordless phone radiation safety level
- Microwave oven leakage detection
- Personal living environment EMF safety
Technical Specifications
| Sensor Type | Electric field (E) |
| Frequency Range | 10 MHz to 8 GHz |
| Directional Characteristic | Isotropic, 3-dimensional |
| Measurement Range | 20 mV / m to 108.0 V / m |
| (CW Signal > 10 MHz) | 53 mA / m to 286.4 mA / m 1 μW or m2 to 30.93 W / m2 0 μW / cm2 to 3.093 mW / cm2 |
| Absolute Error (at 1 V / m and 10 MHz) |
± 1.0 dB |
| Frequency Response | ± 1.0 dB (10 MHz to 1.9 GHz) |
| (Considering Typ. CAL Factor) | ± 2.4 dB (1.9 GHz to 8 GHz) |
| Isotropy Deviation | Type. ± 1.0 dB f > 10 MHz |
| Overload Limit | 10.61 mW / cm2 (200 V / m) |
| Temperature Response (32 °F to 122 °F (0 °C to 50 °C)) |
± 0.5 dB |
| Measurement Method | Digital, triaxial measurement |
| Directional Characteristic | Isotropic, triaxial |
| Measurement Range Selection | One continuous range |
| Display Resolution | 0.1 mV / m, 0.1 μA / m, 0.1 μW / m2, 0.001 μW / cm2 |
| Setting Time | Typically, 1s (0 % to 90 % of meas. value) |
| Display Refresh Rate | Typically, 0.5 Sec |
| Display Type | LCD 4 digit |
| Audible Alarm | Buzzer |
| Measurement Units | mV / m, V / m, μA / m, mA / m, μW / m2, mW / m2, μW / cm2 |
| Measurement Display Value | Instantaneous measured value, maximum value, average value or maximum average value |
| Measurement Alarm Function | Adjustable threshold with ON/OFF |
| Measurement Calibration Factor CAL | Adjustable |
| Manual Data Memory and Read Storage | 99 sets (only recall by meter) |
| Rechargeable Lithium-ion Battery | 3.6 v,1940 mAh charging time approx.3 hours |
| Battery Operation Time | > 10 hours |
| Accessory | carrying case, manual, AC adaptor (DC 5 V 1.5 A), Rechargeable lithium-ion battery |
| Dimensions | Approx. 2.64 in × 2.36 in × 9.72 in (67 mm x 60 mm x 247 mm) |
| Weight | Approx. 8.818 oz (250 g) (including battery) |













Reviews