Enviro Testers Combustible Gas Detector

Enviro Testers combustible gas detector is used for the occasions where rapid detection of combustible gas concentrations, temperature and humidity measurements, and over-standard alarm.

SKU: ETECGD-151 Category:

Overview

Enviro Testers combustible gas detector is used for the occasions where rapid detection of combustible gas concentrations, temperature and humidity measurements, and over-standard alarm. It adopts a high-definition color screen for real-time display, and uses imported gas sensors from well-known brands. The main detection principles are: electrochemical, infrared, catalytic combustion, thermal conductivity, PID. Advanced circuit design, mature kernel algorithm processing, unique shape design, has obtained a few software work patents and appearance patents. It can detect the gas concentration in pipelines or confined spaces and the atmospheric environment. It can detect gas leaks or high purity single gas purity of various background gases such as nitrogen or oxygen. It can detect more than 500 kinds of gases.

 

Key Features

  • The measurement unit can be switched freely
  • Built-in pump suction, integrated water vapor and dust filter
  • Human-machine interface
  • Large-capacity data storage function, support multiple storage methods
  • High temperature gas detection
  • Three display modes can be switched
  • Graphical display to reflect the trend of gas concentration

 

Technical Specifications

Measuring Range 0 ppm to 1 ppm, 0 ppm to 10 ppm, 0 ppm to 100 ppm, 0 ppm to 500 ppm, 0 ppm to 1000 ppm, 0 ppm to 2000 ppm, 0 ppm to 5000 ppm, 0 ppm to 10000 ppm, 0 ppm to 50000 ppm.
0 mg/L to 100 mg/L, 0% LEL to 100% LEL
Resolution 0.001 ppm
0.01 ppm
(0 ppm to 10 ppm), High accuracy
0.01 ppm (0 ppm to 100 ppm),
0.1 ppm (0 ppm to 1000 ppm),
1 ppm (0 ppm to 5000 ppm),
0.01 mg/L,
0.1% LEL 
Working principle Electrochemical, infrared, catalytic combustion, thermal conductivity, semiconductor, PID, etc. Depends on measuring range, field environment and customer requirements.
Sensor Life Electrochemical: 2 years to 3 years
Infrared: 5 years to 10 years
Catalytic combustion: 2 years to 3 years
Thermal conductivity: 2 years to 5 years Semiconductor: 2 years to 3 years
PID: 2 years
Sampling Method Built-in pump suction
Flow: 500 mL/min
Display 2.5 in (63.5 mm) HD color screen 8 keys operation
Accuracy <+2% F.S. (Customizable with higher accuracy)
≤±2%
Linearity Repeatability <±2%
Alarm Sound and light alarm, vibration alarm, visual alarm, sound, and light + vibration + visual alarm, shutdown alarm
Response time ≤20 s
Recovery time ≤30 s
Working power DC 3.7 V
Battery capacity 3.7 V DC, 6000 mA high-capacity rechargeable polymer battery.
With functions of over charge, over discharge, over voltage, over heat, short circuit protection.
Working environment Temp: -40 °F to 158 °F (-40 °C to 70 °C)
Relative humidity: <0% RH to 99% RH (Built-in filter for use in high humidity or dusty environments)
Sample gas temperature -40 °F to 158 °F (-40 °C to 70 °C)
Optional high temperature sampling cooling filter handle to detect 1472 °F (800 °C) or higher gas
Temperature measurement -40 °F to 248 °F (-40 °C to 120 °C)
Accuracy: 32.9 °F (0.5 °C)
Humidity measurement 0% RH to 100% RH
Accuracy: ±3% RH
Data storage Standard configuration is 100,000 pieces of data capacity, support CF card storage. Support local viewing, deletion or data export, free upper computer communication software, storage function is turned off by default, can be set to on, storage interval can be set arbitrarily.
Communication interface USB (Charging and communication)
Infrared or RS 232
Interface language English
Explosion-proof Intrinsically safe Exia CT 4 Ga
Protection IP 67 dust-proof and splash-proof
Dimensions 7 in x 3 in x 1.2 in (180 mm x 78 mm x 33 mm)
Weight 0.7 lb (350 g)