Overview
Enviro Testers Nitrogen N2 Purity Tester is an electrochemistry gas analyzer specifically designed for measuring the purity of nitrogen gas in a range of 0 to 100% volume. It is commonly used in conjunction with nitrogen generators to ensure the quality and reliability of the generated nitrogen gas.
Features
- Rugged and durable: The instrument can effectively resist a three-meter drop. The protection level of the instrument reaches IP67
- Explosion-proof circuit design, safe and reliable: The instrument has got IECEX, ATEX, and the explosion-proof level reaches Exia IICT4 Ga
- Multiple security protection: The alarm function has upgraded the safety of underground operators
Technical Specifications
| Sampling method | pump suction type |
| Gas type | N2 |
| Measure range | 0 to 100 % Vol |
| Resolution | 0.01 % Vol |
| Response time | ≤ 30 seconds |
| Precision | ≤± 2 % F.S except for special gases |
| Automatically test and calibrate after power-on | Including reset, maximum value (MAX), minimum value (MIN), STEL, TWA value |
| Unit | PPM and mg/m³ can be switched and displayed by one key, and the concentration value is automatically converted by the system |
| Display | monochrome graphics (160 x 96), screen can be automatically flipped |
| Backlight | The backlight time can be manually set, and will be turned on automatically when an alarm is issued |
| Data record | Can store 100,000 sets data, the storage interval is adjustable from 5 to 3600 seconds, data can be exported, with data cable |
| Alarm | 95 dB buzzer, vibration alarm and flashing red LED and alarm status indication on the screen, alarm latched; diagnostic alarm and battery undervoltage alarm, pump block alarm; man, down alarm, with early warning and optional real-time remote Bluetooth notification function |
| Battery | 3.7 V rechargeable lithium battery, battery capacity 2200 mA |
| Working hours | More than 15 hours in continuous pumping mode |
| Charger | Travel charger with DC interface, charging time ≥ 4 hours |
| Explosion-proof grade | IECEX/ATEX(II IG Ex ia IIC T4
CNEX:Ex ia IIC T4 Ga |
| Certification
(EU regulations) |
2004/108/EC(EMC) 1995/5/EC(Radio) 94/9/EC(ATEX) |
| Protection grade | IP67 |
| Working temperature | 28 °F to 122 °F (-20 ℃ to +50 ℃) |
| Humidity | 0 to 90 %RH (no condensation) |
| Environmental pressure | 12.49 psi to 15.36 psi (0.86 bar to 1.05 bar) |
| Size | 6.18 in x 3.33 in x 2.34 in (157 mm * 84.5 mm * 59.5 mm) (including back clip/water trap filter) (length * width * height) |
| Weight | 0.805 lb (0.365 kg) (including battery, belt clip and filter) |
Normal gas types and parameters
| Gas | Measure Range | Optional Range | Resolution | Response Time |
| Flammable gas (EX) | 0-100%LEL | 0-100%VOL | 0.1%LEL / 0.1%VOL | ≤10S |
| Oxygen (O2) | 0-30%VOL | 0-25%VOL | 0.01%VOL / 0.1%VOL | ≤10S |
| Carbon monoxide (CO) | 0-1000ppm | 0-2000ppm | 0.1ppm / 1ppm | ≤10S |
| Hydrogen sulfide (H2S) | 0-100ppm | 0-1000ppm | 0.01ppm / 0.1ppm | ≤10S |
| Ammonia (NH3) | 0-100ppm | 0-200ppm | 0.01ppm / 0.1ppm | ≤10S |
| Chlorine (CL2) | 0-10ppm | 0-100ppm | 0.01ppm / 0.1ppm | ≤10S |
| Hydrogen Chloride (HCL) | 0-20ppm | 0-100ppm | 0.01ppm / 0.1ppm | ≤10S |
| Nitric oxide (NO) | 0-100ppm | 0-250ppm | 0.01ppm / 0.1ppm | ≤10S |
| Nitrogen dioxide (NO2) | 0-20ppm | 0-100ppm | 0.01ppm / 0.1ppm | ≤10S |
| Formaldehyde (CH2O) | 0-10ppm | 0-50ppm | 0.01ppm / 0.1ppm | ≤10S |
| Ozone (O3) | 0-10ppm | 0-100ppm | 0.01ppm / 0.1ppm | ≤10S |
| Carbon dioxide (CO2) | 0-2000ppm | 0-100%VOL | 1ppm / 0.01%VOL | ≤10S |