Enviro Testers Multi Parameter ORP Meter

This Multi Parameter ORP Meter Has Measuring Range of -2.000 pH to 20.000 pH, Measuring Range of 2000.0 mV, and ± 0.002 pH of Measurement Accuracy.

SKU: ETEPMWOU-203 Category:

Overview

This Multi Parameter ORP Meter Has Measuring Range of -2.000 pH to 20.000 pH, Measuring Range of 2000.0 mV, and ± 0.002 pH of Measurement Accuracy.

 

Features

  • Automatic temperature compensation ensures high precision measurement over the full-scale range
  • Automatic endpoint lock retains stable readings for easy viewing and recording
  • Interval reading mode periodically sends measured values to a PC or printer
  • Password protection prevents unauthorized calibration and setup
  • Extended memory can store up to 1000 sets of data
  • USB communication interface is easy to connect external devices
  • One key reset automatically restores the meter to the factory default settings

 

Technical Specifications

Measuring Range -2.000 pH to 20.000 pH
 Measurement Accuracy ± 0.002 pH
 Display Resolution 0.01 pH, 0.001 pH, optional
 Calibration Points 1 to 5 points
 pH Buffer Options USA, NIST, DIN, custom
 Measuring Range ± 2000 mV
 Measurement Accuracy ± 0.2 mV
 Calibration Point 1 point (only for relative mV mode)
 Measuring Range 0.001 ppm to 30000 ppm, mg per L, mol per L, mmol per L (depending on the range of the ion selective electrode)
 Measurement Accuracy ± 0.5 % F.S. (one ion), ± 1 % F.S. (two ion)
 Calibration Points 2 to 5 points
 Use Standard Solution 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mg per L, mol per L, mmol per L
 Measuring Range 0.05 mmol per L to 200 mmol per L, 0 °dH  to 1120 °dH, 0 °e to 1404 °e, 0 °fH  to 2000 °fH, 0 mg per L to 8000 mg per L (Ca2+), 0 mg per L to 19999 mg per L (CaCO3), 0 mg per L to 11220mg per L (CaO)
 Measurement Accuracy ± 1 % F.S.
 Calibration Points 2 to 5 points
 Use Standard Solution 0.01 mmol per L, 0.1 mmol per L, 1 mmol per L, 10 mmol per L, 100mmol per L
 Calibration Point 1 point
 Data Lock Manual or Automatic Endpoint Lock
 Data Stability Conditions Standard or high precision
 Calibration Reminder 1 to 31 days or off
 Interval Readings 10, 30, 60 seconds, 10, 30 minutes or off
 Data Storage 1000 groups
 Communication Output USB
 Connector BNC
 Power Type DC 12 V power adapter
 Measuring Range 32 °F to 221 °F (0 °C to 105 °C)
 Measurement Accuracy ± 0.9 °F (± 0.5 °C)
 Temperature Compensation Range 32 °F to 212 °F (0 °C to 100 °C), manual or automatic
Dimensions 9.44 in x 7.87 in x 3.15 in (240 mm × 200 mm × 80 mm)
Meter Weight 3.75 lb (1.7 kg)