This Active Radiation Measuring Equipment has a soil salinity 0 mS/cm to 23 mS/cm, an accuracy of ± 2%, and a resolution of 0.01 mS/cm.

SKU: ETEORM-216 Category:

Features

  • In the plant growth and development process, the radiation factor plays an important role
  • Radiation is the energy of plant photosynthesis,
  • The process of photosynthesis influences the formation of production and product quality
  • Play an important role in the development of plants morphology
  • It leaves shape and size as well as from vegetative growth to reproductive growth rate
  • Used for agriculture, forestry, and other research and production departments
  • Spectral response simulation probe photosynthetic function, digital show, portable
  • Compact, with good accuracy and stability

 

Technical Specifications

Testing Index Parameter
Soil Salinity Range 0 mS / cm to 23 mS / cm

Accuracy ± 2% FS

Resolution 0.01 mS / cm

Soil compaction Range 0 kg / cm² to 89 kg / cm² / (0 kpa to 7922 kpa) / (0 N / cm²) to 890 N / cm²)

Accuracy ± 0.5%

Resolution 1

Dew point (Temp) Range -40.0 °F to 248.0 °F (-40.0 °C to 120.0 °C)

Resolution 0.1 °F (0.1 °C)

Accuracy ±0.4 °F (±0.4 °C)

Light intensity Range 0 Lux to 200000 Lux, Resolution 1 Lux, Accuracy ± 2% FS
Photosynthetically active radiation Range 0 umol / m s to 2700 umol / m s

Resolution 1 μmol / m² s

Accuracy ± 1 μmol / m² s

Wind speed Range Wind speed 0 m / s to 45 m / s

Resolution 0.1 m / s

Accuracy Wind speed ± (0.5 + 0.03 xV) m / s

Rainfall Range 0 mm / min to 4 mm / min

Accuracy ± 0.1 mm

Resolution 0.1 mm

CO concentration Range 0 PPM to 2000 PPM

Accuracy ± (50 PPM +measured value x 3%)
Resolution 1 PPM

Soil temperature Range -58.0 °F to 212.0 °F (-50.0 °C to 100.0 °C)

Accuracy ± 0.5 °F (± 0.5 °C)

Resolution 0.1 °F (0.1 °C)

Soil moisture Range 0% to 100%

Resolution 0.1%

Accuracy ± 2.5% (indoor) ± 5% (outdoor)

pH Range 0 to 14, Accuracy ± 0.5
Total radiation Range 0 w / m² to 2000 w / m²

Accuracy ± 1% (daily accumulation)

Resolution 5 W/m²

Humidity Range 0% to 100% RH

Accuracy ± 3% RH

Resolution 0.1% RH

Dew Point Range -40.0 °F to 248.0 °F (-40.0 °C to 120.0 °C)

Accuracy ± 0.4 °F (±0.4 °C)

Resolution 0.1 °F (0.1 °C)

Temperature Range -40.0 °F to 248.0 °F (-40.0 °C to 120.0 °C)

Accuracy ±0.3 °F (±0.3 °C)

Resolution 0.1 °F (0.1 °C)