Enviro Testers Benchtop Conductivity Ash Meter

This Benchtop Conductivity Ash Meter has resolution of 0.001, 0.01, 0.1, 1, automatic, accuracy: 0.5% F.S, and temperature of 0 to 105°C.

SKU: ETECMTM-212 Category:

Features

  • Professional benchtop conductivity meter is equipped with a 7-inch TFT display
  • 1 to 3 points calibration with automatic recognition for conductivity standards
  • Cell constant, ref. temp, TDS factor, water compensation modes
  • Auto temp compensation corrects conductivity to reference temperature
  • Auto-Read function senses and locks the measurement endpoint
  • Timed Interval Readings sends the measurement data to a PC or printer
  • Limit Alarm automatically alerts when reading exceeds the specified range
  • Calibration due alarm prompts user to calibrate the meter regularly
  • Calibration report shows the date, time, calibration point and factor
  • Password protection prevents the unauthorized calibration and settings
  • Expanded memory stores or recalls up to 1000 data sets
  • Reset function automatically resumes all settings back to the factory defaults

 

Technical Specifications

Conductivity Range 0 µS/cm to 20.00 µS/cm and 200.0 µS/cm to 2000 µS/cm
and 20.00 mS/cm and 200.0 mS/cm
Resolution 0.001, 0.01, 0.1, 1, Automatic
Accuracy ±0.5% F.S.
Calibration Points 1 to 3 Points
Calibration Solutions 10 µS or 84 µS or 1413 µS or 12.88 mS or 111.8 mS
TDS Range 0 mg/L to 10 mg/L and 100 mg/L and 1000 mg/L and
10.00 g/L to 200.0 g/L
Resolution 0.01 and 0.1 and 1 and Automatic
Accuracy ±1% F.S.
TDS Conversion Factor 0.1 to 1.0 (Default 0.5)
Salinity Range 0.00 to 80.00 ppt / 0.00 to 42.00 psu / 0.00 to 8.00%
Resolution 0.01
Accuracy ±1% F.S.
Resistivity Range 0.00 MΩ to 30.00 MΩ
Resolution 0.01, 0.1, 1, Automatic
Accuracy ±1% F.S.
Conductivity Ash Range 0.00 to 100%
Resolution 0.01, 0.1, 1, Automatic
Accuracy ±1% F.S.
Temperature Range 32 °F to 221 °F (0 °C to 105 °C)
Resolution 0.1°C/°F
Accuracy ±0.9 °F (±0.5 °C)
Offset Calibration 1 Point
Calibration Range Reading ±10 °C/ °F
Other Specifications Temperature Compensation 32 °F to 212 °F (0 °C to 100 °C), Manual or Automatic
Temperature Coefficient Linear (0.0%/°C to 10.0%/°C) / Non-Linear / Pure Water
Reference Temperature 68 °F or 77 °F (20 °C or 25 °C)
Cell Constant 2-Pole Electrodes (K=0.1 / 1 / 10) or 4-Pole Electrode
Stability Criteria Standard / High-accuracy
Measurement Modes Continuous / Auto-Read Measurement Endpoint
Timed Interval Readings 10 or 30 or 60 sec, 10 or 30 Minutes or Off
Calibration Due Alarm 1 to 31 Days or Off
High/Low Limit Alarm Selectable
Password Protection 4 Digits
Memory Stores Up to 1000 Data Sets
Output USB Communication Interface
Connector 6-pin Mini-DIN, 3.5 mm Jack Socket
Display 7-in TFT LCD
Power Supply 12 V DC Power Adapter
Environmental Conditions 32 °F to 122 °F (0 °C to 50 °C), Relative Humidity <80%
Dimensions 9.44 in × 8.66 in × 3.15 in (240 mm × 220 mm × 80 mm)
Weight 3.74 lb. (1.7 kg)