Enviro Testers Benchtop Ion Meter

This Benchtop Ion Meter has an ion resolution of 0.001, 0.01, 0.1, 1, pH range of -2 pH to 20 pH, and mV calibration range of ±200 mV.

SKU: ETEBIM-219 Category:

Features

  • Auto Temperature Compensation for full-range accuracy
  • Calibration Reminder prompts regular meter calibration
  • Stability indicator shows current measurement status
  • Auto-Hold freezes stable values for easy recording
  • Manual temp calibration enhances measurement accuracy
  • Selectable temp unit (°C/°F) for diverse applications
  • Auto electrode diagnosis reveals offset and slope
  • Help message guides quick meter use
  • System menu adjusts 10 key parameters
  • Reset resumes factory default settings
  • Expanded memory stores up to 500 readings
  • Real-time clock stamps data for GLP compliance
  • USB transfer for data retrieval to computer

 

Technical Specifications

PH Range -2.000 PH To 20.000 PH
PH Accuracy ±0.002 PH
PH Resolution 0.1, 0.01, 0.001 PH, Selectable
PH Calibration Points 1 To 5 Points
PH Calibration Solutions USA, NIST, DIN Or User-Defined
MV Range -1999.9 MV To 1999.9 MV
MV Accuracy ±0.2 MV
MV Resolution 0.1, 1 MV, Selectable
MV Calibration Points 1 Point (Only For Relative MV Mode)
MV Calibration Range ±200 MV
Ion Range 0.001 Ppm To 19999 Ppm, Mg / L, mol / L (Refer To The Range Of ISE)
Ion Accuracy ±0.5% F.S (Monovalent), ±1% F.S (Divalent)
Ion Resolution 0.001, 0.01, 0.1, 1
Ion Calibration Points 2 Points to 5 Points
Ion Calibration Solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 Ppm, mg / L, mol / L
Temperature Range 32 °F To 221 °F (0 °C to 105 °C)
Temperature Accuracy ±0.9 °F (±0.5 °C)
Temperature Resolution 32.18 °F (0.1 °C)
Temperature Calibration Points 1 Point
Temperature Calibration Range Measured Value ±14 °F to ±82 °F (±10 °C)
Compensation Mode/Hold Function Manual or Automatic
Stability Conditions Low or High
Calibration Due 0 To 31 Days
Power Off Manual or Automatic (10, 20, 30 Minutes)
Reset Function Yes
Memory Stores Up to 500 Data Sets
Output USB Communication Interface
Connector BNC
Display LCD 5.11 In x 4.33 in (130 mm × 110 mm)
Power Requirements DC5 V, Using AC Adapter, 220 VAC / 50 Hz
Temperature Compensation 32 °F To 212°F (0 °C to 100°C)
Dimensions 8.26 In × 7.40 in × 2.36 in (210 mm x 188 mm x 60 mm)
Weight 3.30 Lbs. (1.5 kg)

Reviews