Enviro Testers Gas Leakage Detector

This Gas Leakage Detector has temperature range of -40 °F to 2192 °F, an IP 65 dust and water resistance and a reaction time less than 40s.

SKU: ETEOGD-173 Category:

Features

  • Auto temperature compensation
  • Precision filters to remove moisture and dust
  • In-built memory for 2560 records
  • USB port and Bluetooth 4.0 for data transfer
  • Low battery and high alarm reminders
  • IP65 dust and water resistance

 

Technical Specifications

Flue gas CO (with H2-compensation)
Measuring range 0 ppm to 8000 ppm
Accuracy ±10 ppm or ±10% of mv (0 ppm to 200 ppm)
±20 ppm or ±5% of mv (201 ppm to 2000 ppm)
±10% of mv (2001 to 8000 ppm)
Resolution 1 ppm
Reaction time t 90 <40 s
Flue gas CO low
Measuring range 0 ppm to 500 ppm
Accuracy ±2 ppm (0 ppm to 39 ppm)
±5% of mv (40 ppm to 500 ppm)
Resolution 1.0 ppm
Reaction time t 90 <40 s
Flue gas Draught
Measuring range -9.99 hPa to +40 hPa
Accuracy ±0.02 hPa or ±5 hPa (-0.50 hPa to +0.60 hPa)
0.03 hPa to +1 hPa
±1.5% of mv (+3.01 hPa to +40.00 hPa)
Resolution 0.01 hPa with fine draught option 0.001 hPa
Temperature
Measuring range -40 °F to 2192 °F (-40 °C to 1200 °C)
Accuracy ±33 °F (0.5 °C) (32 °F to 212 °F (0 °C to 100 °C))
±0.5 % of mv (Remaining Range)
Resolution 32.5 °F (0.1 °C) (-40 °F to 1830 °F (-40 °C to 999 °C))
33.8 °F (1 °C) (> 1832 °F (1000 °C))
Flue gas degree of effectivity, Eta (calculated)
Measuring range 0% to 120%
Resolution 0.10%
Flue gas loss (calculated)
Measuring range 0% to 99.9 %
Resolution 0.10%
Flue gas CO2 calculation (calculated from O2)
Measuring range 0 to CO2 max (Display range)
Accuracy ±0.2 Vol.%
Resolution 0.1 Vol.%
Pressure measurement
Measuring range 0 hPa to +300 hPa
Accuracy ±0.5 hPa (0.0 hPa to 50.0 hPa)
±1% of mv (50.1 hPa to 100.0 hPa)
±1.5% of mv (Remaining Range)
Resolution 0.1 hPa with fine draught option 0.01 hPa