| pH |
|
| Range |
-2.000 pH to 20.000 pH |
| Accuracy |
±0.002 pH |
| Resolution |
0.1 pH, 0.01 pH, 0.001 pH, Selectable |
| Calibration Points |
1 point to 5 points |
| Calibration Solutions |
USA, NIST, DIN or User-defined |
| Temperature Compensation |
32 °F to 212 °F (0 °C to 100 °C) |
| Compensation Mode |
Manual or Automatic |
| mV |
| Range |
-1999.9 mV to 1999.9 mV |
| Accuracy |
±0.2 mV |
| Resolution |
0.1 mV, 1 mV, Selectable |
| Calibration Points |
1 point (Only for Relative mV mode) |
| Calibration Range |
±200 mV |
| Ion |
| Range |
0.001 ppm to 19999 ppm, mg / L, mol / L (Refer to the range of ISE) |
| Accuracy |
±0.5% F.S (Monovalent), ±1% F.S (Divalent) |
| Resolution |
0.001, 0.01, 0.1, 1 |
| Calibration Points |
2 points to 5 points |
| Calibration Solutions |
0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mg / L, mol / L |
| Temperature Compensation |
32 °F to 212 °F (0 °C to 100 °C) |
| Compensation Mode |
Manual or Automatic |
| Conductivity |
|
| Range |
0 µS/cm to 20.00 µS/cm, 200.0 µS/cm, 2000 µS/cm, 20.00 mS/cm, 200.0 mS/cm |
| Accuracy |
±0.5% F.S |
| Calibration Points |
1 point to 5 points |
| Calibration Solutions |
10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm |
| Temperature Compensation |
32 °F to 212 °F (0 °C to 100 °C) Manual or Automatic |
| Temperature Coefficient |
0.0% to 10.0% / °C |
| Compensation Modes |
Linear or Pure Water |
| Cell Constant |
K=0.1, 1, 10 or User-defined |
| Normalization Temperature |
68 °F (20 °C) or 77 °F (25 °C) |
| TDS |
|
| Range |
0 ppt to 100 ppt (Max. 200 ppt, depending on factor setting) |
| Accuracy |
±1% F.S |
| TDS Factor |
0.1 to 1.0 (Default 0.5) |
| Salinity |
|
| Range |
0 ppt to 10 ppt (Max. 80 ppt) |
| Accuracy |
±1% F.S |
| Measurement Modes |
Seawater or Practical Salinity |
| Resistivity |
|
| Range |
0 MΩ to 100 MΩ |
| Accuracy |
±1% F.S |
| Resolution |
0.01, 0.1, 1 |
| Dissolved Oxygen |
|
| Range |
0.00 mg / L to 20.00 mg / L (or ppm) |
| Accuracy |
±0.2 mg / L |
| Resolution |
0.01 mg / L |
| Calibration Points |
1 point or 2 points |
| Temperature Compensation |
32 °F to 122 °F (0 °C to 50 °C) Automatic |
| Pressure Correction |
0.6 bar to 1.125 bar (60.0 kPa to 112.5 kPa), 450 mmHg to 850 mmHg |
| Salinity Correction |
0 g/L to 50 g/L |
| % Saturation of Oxygen |
|
| Range |
0.0% to 200.0% |
| Accuracy |
±2.0% |
| Resolution |
0.1, 1% |
| Temperature |
|
| Range |
32 °F to 221 °F (0 °C to 105 °C) |
| Accuracy |
±0.9 °F (±0.5 °C) |
| Resolution |
0.18 °F (0.1 °C) |
| Calibration Points |
1 point |
| Calibration Range |
Measured value ±50 °F (±10 °C) |
| Others |
|
| Hold Function |
Manual or Automatic |
| Stability Conditions |
Low or High |
| Calibration Due |
0 to 31 days |
| Power Off |
Manual or Automatic (10 minutes, 20 minutes, 30 minutes) |
| Reset Function |
Yes |
| Memory |
Stores up to 500 data sets |
| Output |
USB Communication Interface |
| Connector |
BNC, 6-pin Mini Plug |
| Power Requirements |
3 × 1.5 V “AA” Batteries |
| Battery Life |
Approximately 150 hours (Turn off the backlit) |
| Dimensions |
6.69 in × 3.34 in × 1.18 in (170 mm × 85 mm × 30 mm) |
| Weight |
0.66 lb (300 g) |