Enviro Testers Water Quality Meter with 12 Multiparameter (Data Storage)

This Water Quality Meter with 12 Multiparameter (Data Storage) is suitable for measuring the pH, mV, Conductivity and TDS of liquids and comes with an extended data storage memory of up to 500 readings.

SKU: GTOOYYOOZW Category:

Overview

Enviro Testers Water Quality Meter with 12 Multiparameter (Data Storage) is suitable for measuring the pH, mV, Conductivity and TDS of liquids. In the Conductivity/TDS mode the instrument features 1 to 5 points push-button calibration with automatic calibration solution recognition, selectable cell constant (0.1/1/10), normalization temperature, TDS conversion factor and linear or pure water compensation mode. System menu allows setting the 12 parameters, including the number of calibration points, resolution, stability condition, measurement unit, etc. Stored data can be transferred into computer by USB communication interface.

 

Key Features

  • Equipped with a large backlit LCD display
  • In pH mode, Ito 5 points push-button calibration with auto-buffer recognition and in conductivity/TDS Mode 1 to 5 points push-button calibration with automatic calibration solution recognition
  • Automatic electrode slope display helps user decide whether to replace sensor
  • Selectable cell constant (0.1/1/10), normalization temperature 68 °F/77 °F (20 °c /25°C), TDS conversion factor and linear or pure water compensation mode.
  • Automatic Temperature Compensation provides accurate reading over the entire range
  • Calibration Due Reminder prompts user to calibrate the meter regularly
  • Stability indicator automatically shows current measurement status
  • Auto-Hold function freezes stable measured value for easy viewing and recording
  • Manual temperature calibration corrects temperature deviation
  • Selectable temperature unit (°C or °F) meets different application requirements
  • Automatic electrode diagnosis shows zero point offset and slope of the electrode
  • Help message is an operational guide that helps user quickly begin using the meter
  • System menu allows setting the 12 parameters, including the number of calibration points, resolution, stability condition, measurement unit, etc
  • Reset feature automatically resumes all parameters back to factory default settings
  • Expanded memory stores and recalls up to 500 readings
  • Built-in real-time clock stamps stored data to meet GLP standard
  • Stored data can be transferred into computer by USB communication interface.

 

Technical Specifications

pH
Range -2.000 pH — 20.000 pH
Accuracy +-0,002 pH
Resolution 0.1 pH, 0.01 pH, 0.001 pH (selectable)
Calibration Points 1 to 5 points
Calibration Solutions USA, NIST, DIN or User-defined Buffer
Temperature Compensation 32 °F – 212 °F (0 °C – 100 °C)
Compensation Mode Manual or Automatic
mv
Range -1999.9 mV — 1989.9 mV
Accuracy +-0.2 mV
Resolution 0.1 mv, 1 mV (Selectable)
Calibration Points 1 point (Only for Relative mV mode)
Calibration Range +-200 mV
lon
Range 0.001 ppm – 19999 ppm, mg/L, mol/L (depending on the range of ISE)
Accuracy +-0.5 % F.S (monovalent), +1 % F.S (divalent)
Resolution 0.001, 0.01, 0.1, 1
Calibration Points 2 to 5 points
Calibration Solutions 0.001 ppm, 0.01 ppm, 0.1 ppm, 1 ppm, 10 ppm, 100 ppm, 1000 ppm, 10000 ppm, mg/L, mol/L
Temperature Compensation 32 °F — 212 °F (0 °C – 100 °C)
Compensation Mode Manual or Automatic
Conductivity
Range Ous/em — 20.00 ps/cm, 200.0 ps/em, 2000 ps/cm, 20.00, 200.0 ms/cm
Accuracy +-0.5% FS
Calibration Points 1to 5 points
Calibration Solutions 10 ps/cm, 84 pS/cm, 1413 pS/em, 12.88 mS/cm, 11.8 ms/cm
Temperature Compensation 32 °F — 212 °F (0 °C – 100 °C), Manual or Automatic
Temperature Coefficient 0.0 %/°C – 10.0 %/°C
Compensation Modes Linear or Pure Water
Cell Constant K=0.1, 1, 10 or User-defined
TDS
Range 0 ppt – 100 ppt (Max. 200 ppt, depending on factor setting)
Accuracy +-1%FS
TDS Factor 0.1 – 1.0 (Default 0.5)
Salinity
Range 0 ppt — 10 ppt (Max. 80 ppt)
Accuracy +-1%FS
Measurement Modes Seawater or Practical Salinity
Resistivity
Range 0 MQ – 100 MQ
Accuracy +-1%FS
Resolution 0.01, 0.1, 1
Dissolved Oxygen
Range 0.00 mg/L – 20.00 mg/L (or ppm)
Accuracy +-0.2 mg/L
Resolution 0.01 mg/L
Calibration Points 1 or 2 points
Temperature Compensation 32 °F – 122 °F (0 °C – 50 °C), Automatic
Pressure Correction 60.0 kPa – 112.5 kPa, 450 mm Hg – 850 mm Hg
Salinity Correction Og/L-50 g/t
Saturation of Oxygen
Range 0.0 % – 200.0 %
Accuracy +-2.0 %
Resolution 0.1%,1%
Temperature
Range 32 °F — 221 °F (0 °C – 105 °C)
Accuracy +0.5 °C, 0.9 °F
Resolution 32118 F (0.1 °C)
Calibration Points 1 point
Calibration Range Measured value +(10 °C) 50 F
Others
Hold Function  Manual or Automatic
Stability Conditions Low or High
Calibration Due  0 to 31 days
Power Off Manual or Automatic (10 minutes, 20 minutes, 30 minutes)
Reset Function Yes
Memory Stores up to 500 data sets
Output USB Communication Interface
Connector BNC, 6-pin Mini Plug
Display  LCD
Power Requirements DC 5 V, using AC adapter, 220 V AC/50 Hz
Dimensions 8.2 in x 7.4 in x 2.3 in (210 mm * 188 mm x 60 mm)
Weight 3.3 Ibs (1.5 kg)