Surface Contamination Detector for Radiation Monitoring – Enviro Testers

Surface Contamination Detector for Radiation Monitoring is a portable surface pollution measuring instrument.

SKU: ETERM-424 Category:

Overview

Enviro Testers Surface Contamination Detector for Radiation Monitoring is a portable surface pollution measuring instrument. The instrument uses a large-area double crystal detector, which can measure α and β at the same time. Surface contamination detector for radiation monitoring is mainly used to detect the surface contamination of the ground and tabletops in radioactive workplaces, as well as the contamination of workers’ hands, shoes, work clothes and other surfaces. This instrument can be used in nuclear medicine, decommissioning of nuclear facilities, nuclear waste treatment, nuclear power plants, environmental monitoring and military nuclear detection and other radiation detection. The instrument adopts a replaceable rechargeable lithium battery, a 3.5-inch wide viewing angle IPS bright LCD display, and a multi-button design, which is easy to operate and easy to use.

 

Features

  • Capable of measuring α-, β-, and γ-contamination simultaneously or separately with shortcut key switches.
  • ZnS + plastic scintillator dual crystal detector.
  • Aluminum-plated polyester film on the probe membrane.
  • Allows for background deduction and supports editing and adding up to 45 nuclides in its library.
  • Sound and light alarm with LCD indication.
  • Stores no less than 10,000 groups of data with power-off protection. Supports USB and optional wireless data transmission.
  • Capable of switching between cps, Bq, and Bq/cm².
  • Background counts are α < 0.2 cps, β ≤ 2.0 cps (with an environmental γ background of 0.20 μGy/h).
  • α is lower than 0.028 Bq/cm², β is lower than 0.48 Bq/cm².
  • Typical efficiency (2π) for Sr-90/Y-90(β) ≥ 40%, Cl-36(β) ≥ 20%, Am-241 (α) ≥ 35%.
  • Relative inherent error better than ±10% and measurement repeatability better than ±10%.
  • Adjustable within the measurement range.
  • Operating temperature of -10°C to 40°C and working humidity ≤ 90% (at 35°C without condensation).

 

Technical Specifications

Detector Dual crystal detector
Light Detection PMT (Photomultiplier Tube)
Measurement Mode – α, β simultaneous measurement or total count measurement

– CPS and Bq/cm² mode switching

Detector Size 4.5 in x 5.86 in (11.5 cm × 14.9 cm)
Sensitive Field 170 cm²
Incident Window Aluminized film
Protection Grid Transmittance ≥80%
Display 3.5-inch IPS wide viewing angle LCD display
Measuring Time 1 s to 9999 s (continuously adjustable)
Alarm Threshold Continuously adjustable within the measurement range
Nuclide Library Built-in (customizable to add nuclides)
Data Transmission USB or wireless communication
Battery 218650 rechargeable and replaceable lithium batteries
Sensitivity
Background – ≤0.1 cps (α channel, environmental background < 0.15 μSv/h)
– ≤8 cps (β channel, environmental background < 0.15 μSv/h)
Efficiency – α: ≥35% (239Pu, 2π, source-detector distance ≤5 mm)
– β: ≥40% (90Sr-90Y, 2π, source-detector distance ≤10 mm)
Measuring Range – 0 cps to 10000 cps (α channel)
– 0 cps to 50000 cps (β channel)
Environmental Conditions
Working Temperature 14°F to 104°F (-10°C to +40°C)
Storage Temperature -4°F to 131°F (-20°C to +55°C)
Relative Humidity 0% to 90% (at 86°F (30°C), no condensation)
Protection Class IP53
Maximum Working Time 24 hours (default setting state)
Size 9.05 in x 4.72 in x 5.51 in (23 cm × 12 cm × 14 cm (including handle))
Weight (with battery) 56.43 oz (1600 g)