High Precision Zirconia Oxygen Gas Analyzer Fixed Detector – Enviro Testers

Smart zirconia oxygen analyzer with fast 4–7s response, modular design, and explosion-proof durability for combustion control.

SKU: ETEHPOGD-425 Category:

Overview

Enviro Testers High Precision Zirconia Oxygen Gas Analyzer Fixed Detector is designed for continuous and accurate measurement of oxygen concentration in combustion exhaust gases from industrial boilers, furnaces, and process systems. This device utilizes a zirconia sensor with direct insertion, eliminating the need for additional gas sampling equipment.

 

Features

  • High-precision zirconia oxygen measurement in non-combustible gases
  • Direct insertion type design; no gas sampling devices required
  • Modular sensor design for easy replacement and maintenance
  • Fast response time of 4–7 seconds
  • Explosion-proof and pressure-proof construction with IP66/IP67 rating
  • Stable long-term use with advanced sensor diagnostic functions
  • Supports digital display and RS485/HART communication options
  • Wide gas temperature measurement range up to 1500 °C
  • Durable construction with SUS316 explosion-proof filters

 

Application

Ideal for combustion management, exhaust gas monitoring in industrial boilers, furnaces, and other high-temperature process applications.

 

Technical specifications

Specification Description
Measuring Object Oxygen in non-combustible gas
Measuring Method Insertion type zirconia sensor
Measuring Range 0 to 2% or 0 to 50% O₂ (in 1% O₂ steps)
Repeatability Within ±0.5% FS
Linearity Within ±2% FS
Zero Offset Within ±2% FS per month
Response Time 4 to 7 seconds for 90% (from calibration gas inlet)
Warm-up Time More than 10 min
Analog Output 4 to 20 mA DC, linear, isolated
Communication (Optional) HART or RS-485 (MODBUS)
Contact Output 6 points, SPST-NO, 250 V AC/30 V DC, 3 A
Contact Input 3 points ON; 0 V (10 mA or less), OFF; 5 V
Power Supply AC 100–120 V or AC 200–240 V
Concentration Display Digital indication in 4 digits
Detector Gas Temp. Range -10 °C to +600 °C (Flow guide tube system)

-10 °C to +1500 °C (Ejector system, high-temp gas)

-10 °C to +800 °C (Ejector system, general-use)

Gas Pressure Range 3 to +3 kPa
Filter Aluminum oxide, quartz paper, SUS316 explosion-proof filter
Housing Protection Rating IP65/IP66/IP67 (depending on model)
Weight Ordinary type: 3.52 lb (1.6 kg); Explosion-proof type: 6.61 lb (3 kg)

Reviews

There are no reviews yet.

Be the first to review “High Precision Zirconia Oxygen Gas Analyzer Fixed Detector – Enviro Testers”

Your email address will not be published. Required fields are marked *